REHABILITATION OF MEDIUM-VOLTAGE RECLOSERS AT LA PEDRERA SUBSTATION: ADAPTATION OF COOPER–ROCKWILL SYSTEMS TO IMPROVE POWER SUPPLY RELIABILITY
Main Article Content
Abstract
The La Pedrera substation, a critical node in the electrical supply for the communities of Guaimaral and Abejales, faced a high risk of catastrophic failure due to severe physical deterioration and electronic malfunctions (IGBT failures) in its 13.8 kV medium-voltage reclosers. This study presents the methodology, implementation, and results of a rehabilitation project focused on the technical adaptation of Cooper recloser tanks—whose insulation ratings exceeded those of the existing Rockwill control cabinets. Through an applied research approach, a customized control interface was designed and deployed to overcome the logical incompatibility between both systems. The results demonstrate the technical and economic feasibility of the solution, validated through comprehensive no-load testing, under-load verification, and post-intervention monitoring. The adaptation not only yielded significant savings in cost and execution time but also eliminated malfunction incidents, resulting in measurable improvements in the reliability and availability of the electrical supply for the affected communities.
Downloads
Article Details

This work is licensed under a Creative Commons Attribution 4.0 International License.
References
Bancayán, F., & Albán, J. (2024). Desarrollo de un algoritmo basado en redes neuronales para la selección de ajustes automatizado de reconectadores de media tensión [Tesis de Licenciatura, Universidad de Piura]. https://hdl.handle.net/11042/6984.
Canchanya, J. (2010). Análisis de la repercusión del campo eléctrico en las pruebas de aislamiento a transformadores de corriente [Tesis de Licenciatura, Universidad Nacional del Centro del Perú]. http://hdl.handle.net/20.500.12894/3580.
Cooper Power Systems. (2012). Restauradores (reconectadores): Tipos NOVA 15, NOVA 27 y NOVA 38; trifásicos controlados por microprocesador: Instrucciones de instalación y funcionamiento (Boletín de servicio S280-42-1S) [Folleto técnico]. https://studylib.net/doc/25241790/s280421s.
Enel Colombia. (2024). LA503 Línea 13,2–11,4 kV: Montaje de reconectador con transformador de potencial (Norma técnica LA503, rev. 3). Likinormas. https://likinormas.enelcol.com.co/node/299/pdf.
Gómez, E., & Solarte, J. (2023). Automatización inteligente mediante reconectadores en redes de distribución. Ingeniería y Competitividad, 25(Suplemento). https://doi.org/10.25100/iyc.v25iSuplemento.13167.
International Electrotechnical Commission. (2000). Function blocks for industrial-process measurement and control systems – Part 1: Architecture (IEC PAS 61499-1:2000). IEC. https://webstore.iec.ch/en/publication/20597.
Mendoza, F. (2022). Validación de la guía técnica para la instalación de reconectadores en 44 kV. [Tesis de Licenciatura, Universidad de Antioquia]. https://hdl.handle.net/10495/28964.
Quito, B., & Reyes, D. (2023). Parametrización y puesta en servicio de un Intellirupter instalado en la red de medio voltaje de un alimentador primario de distribución [Tesis de Licenciatura, Universidad Politécnica Salesiana]. http://dspace.ups.edu.ec/handle/123456789/26170.
Rockwill Electric Group. (s. f.). RWK series automatic recloser controller manual (6 kV…40,5 kV) [Manual técnico]. https://www.scribd.com/document/522942480/Controller-RWK.
Superintendencia General de Electricidad y Telecomunicaciones. (SIGET). (2000). Normas técnicas de diseño, seguridad y operación de las instalaciones de distribución eléctrica (Acuerdo n.° 29-E-2000). https://www.siget.gob.sv/gerencias/electricidad/normativas-de-electricidad/infraestructura-para-la-distribucion-electrica/.



